DTH-800
The Airflow Systems line of downdraft tables brings source capture collection efficiency to industrial applications requiring larger, open collection areas and work surfaces. The Airflow Systems downdraft table combines the work surface with the particulate collection area. The downdraft design draws contaminants away from the worker's breathing zone without hindering the worker's movement or productivity. Airflow Systems offers a selection of portable downdraft tables and stationary downdraft tables for most any type of grinding, sanding, and welding application.
Features & Benefits
Integral collection area and work surface: Draws contaminants away from workers’ breathing zone without hindering movement; easily moved to any location in facility.
Direct-Drive Blower: Higher static pressure, longer filter life and greater reliability; spark resistant; no belts or pulleys to replace.
Non-electrostatic operation: High reliability, low maintenance.
Compressed filter mounting: Eliminates contaminant bypass of filters.
Low profile cabinet Easy access speeds filter changeout and maintenance.
Vibra-Pulse® Filter Cleaning System: Cleans filters 75% more effectively than reverse pulse systems.
Dust Drawer: Easily remove external dust drawer with positive lever lock.
Options
Pressure Gauge Kit: Indicates when filters require cleaning.
Regulator
Silencer: Reduces noise by up to 6 dBA.
Custom Cartridge Media: For specific applications.
After-Filters: 99.97% HEPA, 95%, and odor-control modules.
Side Shields: Improves collection efficiency; eliminates contaminant migration.
Enclosures and Lighting: Enhances work area; encourages productivity.
Specifications
Construction: 12/14/16 ga. welded steel, powder coated cabinet
Blower Pkgs (HP): 1.0, 1.5
Noise Level (dBA): 70/74
Electrical: 1 HP - 115/1/60, 12 amps, std.; 1.5 HP - 115/230/1/60, 13.2/6.6 amps, opt.
Nominal Air Flow (CFM): 800
Dimensions
Width: 34.38”
Height: 33.00”
Depth: 31.00”
Table Size: Size: 32.00" W x 24.50" D